Home           Products           Company           Contact us     
> Fundamentals of Control Engineering
> Components and Calibration
> Simple Process Engineering Control Systems
> Complex Process Engineering Control Systems
> Fundamentals of Process Engineering
> Mechanical Process Engineering
> Thermal Process Engineering
> Chemical Process Engineering
> Biological Process Engineering
> Water Treatment
Products  |  Process Engineering  |  Chemical Process Engineering  |  CE 380
CE 380 Fixed Bed Catalysis Show data sheet (pdf file) Print page
Technical Description

  Catalysts enable or accelerate chemical reactions. CE 380 is designed for the decomposition reaction of dissolved saccharose in glucose and fructose.
 
  A hose pump transports the educt (saccharose solution) into bottom of the reactor from a tank. The catalyst takes the form of a fixed bed in the reactor. The saccharose solution flows through the fixed bed. In the process, saccharose is decomposed into glucose and fructose. The catalyst accelerates the reaction and so increases the yield of the product (glucose/fructose mixture). The product is collected in a tank.
  Three reactors allow various catalyses to be compared. The chemical catalyst used is exchanger resin. The recommended biological catalyst is the enzyme invertase. A regulated heating water circuit additionally permits analysis of the influence of temperature on the reaction.
  To determine the glucose concentration in the product, a photometer specifically adapted to the unit is supplied. The photometer data are transferred to a PC and evaluated by software. The flow injection analysis (FIA) CE 380.01 is available as an optional accessory. The FIA enables a larger number of measurements to be performed during the experiment compared to manual analysis, while at the same time reducing the effort involved and improving reproducibility.

 
  The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.

 
Learning Objectives / Experiments
- fundamentals of chemical catalysis
- fundamentals of enzymatic catalysis
- use of a photometric analyser
- drawing up a quantity balance
- determining yield
Features
* Chemical and biological fixed bed catalysis1
* 3 reactors for comparative experiments1
* Product analysis with photometer
Available accessories
CE 380.01 -- Flow Injection Analysis
Alternative products
CE 310 -- Chemical Reactors Trainer
Specification
[1] investigation of catalytic reactions
[2] 3 reactors (PMMA) for comparison of various fixed bed catalyses
[3] hose pump with adjustable speed to transport the educt into the reactors
[4] regulated heating circuit with water tank, heater and pump to regulate the reactor temperatures
[5] 1 scaled container for educt and product respectively
[6] photometer for analysis of the product
[7] software for data acquisition via USB under Window Vista or Windows 7 (photometer)
[8] flow injection analysis (CE 380.01) available as accessory
 
Technical Data

Reactors
- diameter: approx. 10mm
- height: approx. 120mm
Hose pump
- max. flow rate: approx. 28mL/min
Heating circuit pump
- max. flow rate: 10L/min
- max. head: 25m

- power consumption: 120W
Heating circuit

- tank: approx. 7,5L

- heater: approx. 1kW
Tanks for educt and product
- capacity: approx. 2.000mL
- scale division: 50mL
- material: PP
Photometer wavelength: 610nm

 

Dimensions and Weight

LxWxH: 1.000x680x485mm (experimental unit)

LxWxH: 260x260x180mm (photometer)
Weight: approx. 90kg

Required for Operation

230V, 50/60Hz, 1 phase or 120V, 60Hz/CSA, 1 phase

Scope of Delivery

1 experimental unit
1 photometer
1 container of chemical catalyst
1 CD with software for photometer

1 set of hoses

2 light conductors

1 single-end wrench

1 stop watch

1 funnel

3 bottles

1 beaker

1 set of instructional material

Order Details
083.38000  CE 380  Fixed Bed Catalysis
Print