Home           Products           Company           Contact us     
> Fundamentals of Thermodynamics
> Applied Thermodynamics
> Renewable Energies
> Power Engines and Machines
> Internal Combustion Engines
> Refrigeration and Air Conditioning Technology
> Heating and Ventilation in Buildings
> Sanitary Systems
Products  |  Thermal Engineering and HVAC  |  Fundamentals of Thermodynamics  |  WL 376
WL 376 Thermal Conductivity of Building Materials Show data sheet (pdf file) Print page
WL 376 - A product from the GUNT 2E range
Technical Description

  This experimental unit enables experiments to be performed on steady-state heat conduction in non-metallic materials such as polystyrene, PMMA, cork or plaster in accordance with DIN 52612. Specimen sheets are placed between a heater plate and a water-cooled plate. A clamping device ensures that the clamping pressure and thermal contact are reproducible.

  A special sensor measures the heat flux. Electronic controllers keep the temperatures of the heater plate and cooling plate constant within close limits.

  The measured values are transmitted directly to a PC via USB. The data acquisition software is included.

 

Learning Objectives / Experiments
- determination of the thermal conductivity of different
  materials
- determination of the thermal resistance
- thermal conductivity of several specimens
  connected in series (up to a thickness of 50mm)
Features

* Heat conduction in non-metallic materials1
* Material thickness or combinations up to a

  thickness of 50mm can be used

Alternative products
WL 375 -- Advanced Conduction Unit
Specification

[1] determination of the thermal conductivity of building materials
[2] thermal conductivity and thermal resistance measurement in accordance with DIN 52612
[3] reproducible clamping pressure due to clamping device
[4] 8 specimens to be put between hot and cold plate

[5] hot plate with heater mat

[6] cold plate with water cooling and heat flux sensor

[7] software controllers for temperature adjustment of hot and cold plate

[8] 3 temperature sensors for the cooling water: at inlet, at outlet and a mid temperature of the hot and the cold plate

[9] 2 temperature sensors for surface temperature

[10] LabVIEW software for data acquisition via USB under Windows XP or Windows Vista

 

Technical Data

Electric heater mat

- power: 500W

- max. temperature: 200C
Specimens

- lLxW: 300x300mm

- thickness: up to 50mm

- material: Armaflex, grey cardboard, PMMA,

  polystyrene, PS, POM, cork, plaster

Measuring ranges

- temperature: 3x 0...100C, 2x 0...200C

- heat flux density: 0...1.533W/m
 

Dimensions and Weight

LxWxH: 710x430x500mm (experimental unit)

LxWxH: 710x430x200mm (control unit)

Weight: approx. 94kg (total)

Required for Operation
230V, 50/60Hz, 1 phase or 120V, 60Hz/CSA, 1 phase
Cooling water supply and drain required
Scope of Delivery

1 experimental unit

1 control unit

8 specimes

2 hoses

1 LabVIEW software CD + USB cable

1 manual

Order Details
060.37600  WL 376  Thermal Conductivity of
                                 Building Materials
Print
© 2005 G.U.N.T. Gerätebau GmbH