Home           Products           Company           Contact us     
> Fundamentals of Thermodynamics
> Applied Thermodynamics
> Renewable Energies
> Power Engines and Machines
> Internal Combustion Engines
> Refrigeration and Air Conditioning Technology
> Heating and Ventilation in Buildings
> Sanitary Systems
Products  |  Thermal Engineering and HVAC  |  Heating and Ventilation in Buildings  |  HL 351
HL 351 Domestic Heating Boiler Show data sheet (pdf file) Print page
Technical Description

Different operating points can be investigated by changing the oil pressure after the preset boiler water temperature has been reached.

  An integrated hot water circuit with plate heat exchanger simulates the heating circuit in a house. The heat generated can be dissipated via cooling water connections, enabling continuous operation. The heat transferred can be calculated.

  Connections for an external heating circuit are provided on the rear of the boiler. This allows the HL 351 to be expanded into a complete heating system using training panels from the HL series.

 

Learning Objectives / Experiments

- Function of an oil burner
- Operation of a heating boiler with an oil burner
- Burner adjustment during operation
- Temperature measurements in different areas of
  the combustion chamber
- Calculation of the heating capacity of a heating

  boiler
- Function of a plate heat exchanger
- Temperature distributions in a plate heat exchanger

Features
* Trainer for oil burners1
* Transparent oil tank1
* Can be extended to form a complete heating system
Available accessories
HL 860 -- Exhaust Gas Analyser
Alternative products
HL 350 -- Oil Burner Demonstrator
HL 352 -- Domestic Water Heating System
HL 530 -- Training Panel Function of Gas Heater
Specification

[1] Functional heating boiler with oil burner
[2] Boiler with control unit
[3] Heating and cooling circuit equipped with
expansion vessel, pump, boiler safety group,
thermometers, water meter, heat exchanger
[4] Transparent oil tank with filling and bleed
connections

[5] Dissipation of generated heat via plate heat exchanger and cold water connection
 

Technical Data

Boiler

- nominal rating: 17...21kW
- control unit with temperature limiter
Burner

- nominal power: approx. 18kW
Pump

- power consumption: 70W

- max. flow rate: 60L/min

- max. head: 4m

Plate heat exchanger: 3kW, 10 plates
Boiler safety group in accordance with DIN 4751

- 2.5bar

- 50kW
Oil tank: 15L

Water meter: 2.5m/h

 

Measuring ranges
- temperature: 1x 0...120C / 2x 0...80C
  

Dimensions and Weight
l x w x h: 1100 x 740 x 1700 mm
Weight: approx. 200 kg
Required for Operation

230V, 50/60Hz, 1 phase or 120V, 60Hz, 1 phase

Cold water connection

Scope of Delivery

1 trainer

1 manual

Order Details
065.35100  HL 351  Domestic Heating Boiler
Print
© 2005 G.U.N.T. Gerätebau GmbH