ET 101 Simple Compression Refrigeration Circuit Show data sheet (pdf file) Print page
ET 101 - A product from the GUNT 2E range
Technical Description

  The purpose of a refrigeration system is the cooling of materials and products, e.g. to protect food from spoiling. Cooling can be described as a process in which heat is removed from the environment.
  A commonly used refrigeration system is the so-called compression refrigeration system. In this system refrigerant flows through four main elements: compressor, condenser, expansion element and evaporator. The refrigeration system uses the fact that the refrigerant has a low boiling point at low pressure. This means that evaporation takes place on the low pressure side. During the evaporation of the refrigerant heat is removed from the environment and it is cooled. The condensation takes place on the high pressure side after the evaporator. Here the heat is discharged into the environment. If not the cooling effect but the discharged heat is used, this is called a heat pump.
  The set-up of ET 101 represents a simple compression refrigeration system. Evaporator and condenser have been designed as a pipe coil with each end immersed in a water-filled tank. The water simulates the environment. A thermostatic expansion valve serves as expansion element. Two manometers indicate the two system pressures on the high and low pressure sides. On an additional scale on the manometer the evaporation temperature of the refrigerant is indicated. Two thermometers measure the temperature of the water in the tanks.

  This allows for calculations of the amount of heat removed from the environment (evaporator, cold water) and added to the environment

(condenser, hot water). A sight glass indicates the aggregate state of the refrigerant upstream of the expansion valve.
  The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.

 

Learning Objectives / Experiments

- fundamentals of a compression refrigeration circuit
- key components of a refrigeration system
  * compressor, evaporator, condenser, expansion

    element
- relationship between the pressure and boiling

  point of a liquid
- operation of a refrigeration system / heat pump
- developing a basic understanding of the

  thermodynamic cycle
- simple energy balance

Features

* Introduction to refrigeration1
* Model of a compression refrigeration system /

  heat pump1
* Cooling and heating of the heat exchangers

  directly tangible

Alternative products
ET 350 -- Changes of State in the Refrigeration Circuit
ET 480 -- Absorption Refrigeration System
Specification

[1] fundamentals of refrigeration in a simplified model
[2] typical compression refrigeration system with piston compressor, thermostatic expansion valve, evaporator and condenser (each in the shape of a pipe coil)
[3] 2 manometers with temperature scale for the refrigerant show the values of the refrigerant on the high and low pressure sides
[4] 2 water-filled tanks with thermometer to demonstrate the cooling and heating effect
[5] pressure switch to protect the compressor
[6] sight glass to monitor the aggregate state of the refrigerant
[7] refrigerant R134a, CFC-free

  

Technical Data
Compressor
- power consumption: 69,7W at 0/55C
- refrigeration capacity: 82,6W at 0/55C
- displaced volume: 1,41cm
Manometer with temperature scale for R134a
- intake side (low pressure)
  pressure: -1...9bar
  temperature: -50...40C
- delivery side (high pressure)
  pressure: -1...24bar
  temperature: -40...80C
Thermometer: 2x -10...50C
Tank: 4x 1.700ml
 
Dimensions and Weight
LxWxH: 750x360x690mm
Weight: approx. 30kg
Required for Operation
230V, 50/60Hz, 1 phase or 120V, 60Hz/CSA, 1 phase
Scope of Delivery

1 experimental unit, filled with refrigerant

4 water tanks

2 thermometers

2 spoons

1 set of instructional material

Order Details

061.10100  ET 101  Simple Compression

                                 Refrigeration Circuit