Products  |  Process Engineering  |  Simple Process Engineering Control Systems  |  RT 450.04
RT 450.04 Controlled System Module: Temperature Show data sheet (pdf file) Print page
Technical Description

  The RT 450.04 controlled system module is a panel-mounted ready-to-install element. In conjunction with other modular control components, it enables temperature control systems with different characteristic features to be constructed and investigated.

 

  The panel is mounted on the frame of the base module RT 450. The main elements of the controlled system module are: an electric heater installed in a section of pipe, and a plate heat exchanger between the primary and secondary water circuits. The heater can either be operated by a switching controller and so act as the control loop actuator, or can operate in continuous duty as a pure energy source. In operation as a continuous controller, with the heater as the energy source, a choice of two different valves (pneumatic or electric) can be used as actuators in the primary circuit.

 
  For safety, the heater features a thermostat and a device to protect it from running dry. The primary circuit (with heater) is connected by pipelines to the water supply of the base module RT 450, while the secondary circuit requires a laboratory water supply for cooling. Counterflow or parallel flow cooling is possible. The connection to the laboratory network is made by quick-release couplings and hoses.

  

Learning Objectives / Experiments

- planning, setting up, testing, optimising and

  assessing temperature control loops with different

  objectives and components
- design and function of
different instrumentation

  and control components
- technical terminology and
symbols in industrial

  control engineering
- practical exercises: implementing process and

  signal lines
- commissioning and troubleshooting of process

  engineering systems

Features

* Main element in constructing a temperature control

  loop1
* Rapid installation into the RT 450 base module by

  modular panel assembly

Available accessories
RT 450 -- Process Automation Training System: Base Module 
RT 450.10 -- Continuous Controller Module
RT 450.11 -- Switching Controller Module
RT 450.12 -- Chart Recorder Module
RT 450.13 -- Digital Display
RT 450.14 -- Software for Controller Configuration
RT 450.21 -- Control Valve, Pneumatically Driven, Kvs 1,0
RT 450.24 -- Control Valve, Electrically Driven, Kvs 1,0
RT 450.36 -- Temperature Sensor PT100
RT 450.37 -- Thermocouple (K) with Head Transmitter
RT 450.40 -- Visualisation Software
RT 450.41 -- Profibus DP Module for Controller
RT 450.42 -- PLC Module with Software
RT 450.43 -- Profibus DP Module for PLC
Alternative products
RT 040 -- Training System: Temperature Control, HSI
RT 542 -- Temperature Control Trainer
RT 644 -- Temperature Control Demonstration Unit
Overview
RT 450 Modular Process Automation Training System
Specification

[1] construction of a temperature control loop (in conjunction with other modules of the RT 450 series)
[2] ready-to-install compact panel assembly
[3] electric heater with thermostat and dry-running protection
[4] direct temperature display at heater outlet with bimetallic thermometer
[5] heater is either an actuator or a continuous heater
[6] plate heat exchanger, operating in counter-flow or parallel-current mode
[7] primary circuit with heater and heat exchanger, connected to water supply of base module RT 450
[8] flow of primary circuit controlled by hand-operated valve
[9] secondary circuit of heat exchanger connected to laboratory water supply

 

Technical Data

Plate heat exchanger
- number of plates: 20
- heat transfer surface: 0,72m
- flow rate: max. 3m/h
 
Heater with thermostat and dry-running protection
- power output: 2kW
- temperature limitation by thermostat: 65C
 
Thermometer at heater outlet: 0...100C

 

Dimensions and Weight
LxWxH: 510x200x650mm
Weight: approx. 20kg
Required for Operation
Water connection: max. 3m/h
Scope of Delivery
1 heater and 1 plate heat exchanger mounted on panel, complete with piping, valve, safety elements, temperature sensor fixtures, connections to RT 450 piping system
Order Details

080.45004  RT 450.04  Controlled System Module:

                                      Temperature


Print
© 2005 G.U.N.T. Gerätebau GmbH