Home           Products           Company           Contact us     
> Fundamentals of Thermodynamics
> Applied Thermodynamics
> Renewable Energies
> Power Engines and Machines
> Internal Combustion Engines
> Refrigeration and Air Conditioning Technology
> Heating and Ventilation in Buildings
> Sanitary Systems
Products  |  Thermal Engineering and HVAC  |  Refrigeration and Air Conditioning Technology  |  ET 915.07
ET 915.07 Air Conditioning Model Show data sheet (pdf file) Print page
Technical Description

  ET 915.07 is part of the HSI training system for refrigeration and air conditioning technology. In combination with the base unit ET 915 the operational model of a full air conditioning system is created. The model is plugged onto the base unit, secured using fasteners and connected with refrigerant hoses to become a complete refrigeration circuit for the air cooler.
  The room climate is created by the interaction of air temperature, heating temperature and air humidity. The purpose of room air conditioning is to shape the room climate in accordance with the requirements of people or sensitive goods. This model introduces the operation of an air conditioning system and the recirculating air and outer air operating modes.
  The model ET 915.07 includes two air ducts with transparent front. The top air duct serves as climatic chamber whilst the bottom air duct contains the air cooler, two electric air heaters and a steam humidifier. A fan between the two air ducts recirculates the air. A motorised butterfly valve in the top air duct allows a change between outer air and recirculating operation. Dependent on the switching of the two air heaters, the air cooler and the humidifier, the air in the duct system can be cooled, heated, humidified or dehumidified.
  The individual system components are controlled via the educational software which is included in the scope of delivery of the base unit ET 915. Temperature and humidity before and after the evaporator and

in the climatic chamber are recorded by sensors, digitised and represented dynamically in the educational software. The conditioning of the air can be monitored online in the h-x diagram.

 

Learning Objectives / Experiments

- Full air conditioning system and its main

  components
- Heating and cooling in the h-x diagram
- Humidifying and dehumidifying in the h-x diagram
- Outer air and recirculating operation
- Fault simulation

Features

* Complete model of a full air conditioning system1
* Heating, cooling, humidifying and dehumidifying1
* Outer air and recirculation operation possible1
* Component control and fault simulation via the

  educational software

Available accessories
ET 915 -- HSI Training System Refrigeration and Air Conditioning Technology, Base Unit
Alternative products
ET 915.06 -- Model of a Simple Air Conditioning System
Specification
[1] Model of an air conditioning system to plug onto the base unit ET 915
[2] GUNT training system with HSI technology
[3] Air duct with transparent front and adjustable ventilation flap for recirculating or outer air operation
[4] Evaporator as air cooler
[5] 2 heaters as air preheater and reheater
[6] Air humidifier with float switch, fan, filling level indication
[7] Thermostatic expansion valve as expansion element
[8] Sensor to record temperature and combined sensor for humidity and temperature
[9] Units and fault simulation controlled via educational software
 
Technical Data
Air duct, top: 136x136x800mm
Evaporator as air cooler
- transfer area: approx. 900cm
Air heater: 2x 250W
Axial fan
- max. power consumption: 19W
- max. flow rate: 160m/h
Humidifier
- heater: 200W
Servomotor for ventilation flap: 24VDC
 
Measuring ranges
- temperature: 2x -50...50C, 4x 0...50C
- humidity: 4x 10...100% r.h.
 
Dimensions and Weight
LxWxH: 850x400x680mm
Weight: approx. 51kg
Scope of Delivery
1 air conditioning system model, filled with refrigerant
Order Details
061.91507  ET 915.07  Air Conditioning Model
Print