ET 120 Cooling Using the Peltier Effect Show data sheet (pdf file) Print page
Technical Description

  The experimental unit demonstrates cooling using the Peltier effect. Peltier elements utilise the thermoelectric effect of some semiconductors. The thermoelectric effect is the reverse of the known thermopower effect which is e.g. used when measuring temperatures using thermocouplers. If current flows through a Peltier element, one end of the semiconductor becomes hot and the other cold. By a suitable connection of p- and n-doped semiconductor materials the refrigeration capacity can be increased sufficiently to be usable.
  The benefits of cold production using Peltier elements are: Peltier elements are wear and maintenance-free, noiseless, independent of position and easy to adjust in their refrigeration capacity via the supply voltage. In addition, no refrigerants are required. Peltier elements are used for small capacities in thermography as beverage chillers or in medical engineering. Their low efficiency is a disadvantage.
   The experimental set-up is clearly arranged on the front of the experimental unit. The central component of the system is a Peltier element. The heating and refrigeration capacity of the Peltier element are dissipated via water flows. Measuring the respective flow rate and the inlet and outlet temperatures allows for the heat flows to be determined. The supplied electrical power is determined using a current and voltage measurement.
    Due to the closed water circuit the experimental unit can also be operated for short periods of time without being connected to the water mains.

  The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.


Learning Objectives / Experiments

- function and operation of a Peltier element
  * for cooling
  * as heat pump
- determination of the cooling and heating capacity
- recording typical characteristics, such as cooling

  capacity, via temperature differences
- energy balance
- calculating the coefficient of performance



* Demonstration of the thermoelectric effect1
* Creation of energy balances

[1] functional model of a Peltier refrigeration system
[2] experimental unit with clear design of all components at the front
[3] water-cooled Peltier element
[4] shared water circuit for heating and cooling with tank, pump and flow meters
[5] electrical power freely adjustable via potentiometer
[6] digital displays for temperature, current and voltage
[7] flow meter measurement of the water flows via rotameters
Technical Data

Peltier element
- max. refrigeration capacity: 191,4W
- max. current: 22,6A

- max. voltage: 16,9V
- max. temperature difference: 77,8K

- hot side temperature: 50C
- power consumption: 120W
- max. flow rate: 600L/h

- max. head: 30m

Water tank
- content: 7L
Measuring ranges
- current: 0...20A
- voltage: 0...200V
- temperature: 2x -30...80C, 4x 0...100C
- flow rate: 1x 2...27L/h, 1x 10...105L/h


Dimensions and Weight
LxWxH: 1.000x660x560mm
Weight: approx. 60kg
Required for Operation
230V, 50Hz, 1 phase or 120V, 60Hz/CSA, 1 phase
Water connection
Scope of Delivery
1 experimental unit
1 set of instructional material
Order Details

061.12000  ET 120  Cooling Using the Peltier