ET 182 Secondary Controllers in Refrigeration Systems Show data sheet (pdf file) Print page
Technical Description

  So-called secondary controllers are used to ensure the optimum operation of large, complex refrigeration systems. They control the evaporation pressure (KVP), the intake pressure of the compressor (KVL), the delivery capacity of the compressor (KVC), the condensation pressure (WVFX, KVR) and the receiver pressure (KVD, NRD).
  With this trainer the student can try out the operation of the different secondary controllers. The secondary controllers can be disabled as required by bypassing or blocking. This option can be used for fault finding. By adjusting the secondary controllers the effect on the overall system can be studied.
  Manometers at all important locations and a manual thermometer enable the monitoring of the system state. The two evaporators for the cooling and freezing stage can be selected via solenoid valves. With an adjustable electrical heater in the refrigeration chamber the effect of a changing cooling load on the secondary controllers can be examined.
  The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.

Learning Objectives / Experiments

- properties and application options of different

  secondary controllers
  * evaporation pressure controller (KVP)
  * start-up controller (compressor intake control;

  * capacity controller (control of the compressor

    delivery capacity; KVC)
  * condensation pressure controller (WVFX, KVR)
  * receiver pressure controller (KVD with NRD)
- adjustment of optimum operating points
- fault finding in secondary controllers


* Familiarisation with common secondary controllers

  in refrigeration systems1
* Secondary controllers can be decommissioned

  individually for fault finding1
* Refrigeration and freezing stage with cooling load1
* Different secondary controllers at the water-cooled


[1] trainer from the GUNT practical series for the training of mechatronics engineers for refrigeration
[2] refrigeration system with different secondary controllers: evaporation pressure controller KVP, capacity controller KVC, condensation pressure controller KVR, pressure-controlled water valve WVFX as condensation pressure controller, receiver pressure controller KVD, start-up controller KVL
[3] 2 refrigeration chambers: refrigeration and freezing stage
[4] evaporator selectable via solenoid valves
[5] adjustable electric heater in the refrigeration chambers as cooling load
[6] water-cooled coaxial condenser
[7] pressure measurement at all relevant points in the system
[8] refrigerant R134a, CFC-free
Technical Data

Compressor according to CECOMAF
- refrigeration capacity: 990W at -5/55C
- power consumption: 685W
Cooling load: 0...500W
Receiver: 1,3L


Measuring ranges
- pressure: 5x -1...9bar / 3x -1...24bar
- flow rate water: 20...250L/h

- flow rate refrigerant: 1x 1...11,5L/h;  1x 2...27L/h

- temperature: -50...300C

Dimensions and Weight
LxWxH: 2.500x790x1.900mm
Weight: approx. 280kg
Required for Operation
230V, 50Hz, 1 phase
Water connection
Scope of Delivery
1 trainer
1 set of instructional material
Order Details

061.18200  ET 182  Secondary Controllers in

                                Refrigeration Systems

© 2005 G.U.N.T. Gerätebau GmbH